ISM-IDI Engine overspeed Error - Crank Speed Sensor or Camshaft Speed Sensor Failure Red
F5C Reload Engine Dataset Or Replace Engine Controller If Fault Persists (Engine Crank Speed Fault). If EDC Replaced, Follow The Appropriate Service Tool Procedure To Restore Self Learning Parameters. Red
Redundant Engine Speed in Overrun Monitoring -Speed Signal Not Plausible
Partial frosting and sweating of lines combined with poor cooling, fan belt slipping, loss of refrigerant, restricted or clogged liquid line or expansion valve malfunctioning.